Dialogic
®
SS7G2x Signaling Server SGW Mode User Manual Issue 4
6.4.3 ALFCP – Alarm Fault Code Print
Synopsis
This command gives a printout of the alarm class of the specified fault code(s).
The alarm class (CLA) is used to determine whether the alarm is classed as Minor, Major or Critical and in
turn governs the alarm LED, relay and SNMP alarm that are activated when the condition exists.
Each alarm code (CODE) has a factory-set default class. See Chapter 8, “Alarm Fault Code Listing” for the
factory default for each alarm code.
Syntax
ALFCP[:CODE=…];
Prerequisites
None
Attributes
None
Examples
ALFCP;
ALFCP:CODE=8;
Output Format
Alarm Fault Codes
CODE CLA TITLE
8 2 In-band AIS