1 NetVanta Unified Communications Technical Note ___________________________________________________________________________________ Configuring
10 VoIP Host Groups The VoIP Host group identifies the UC server. To configure VoIP Host Groups 1. Using the left-hand menu navigate to Configura
11 4. Select Submit Routing Inbound TDM Calls The Inbound TDM Call Routing table is the main table used to route calls originating from the TDM in
12 Called Number, Called name D D D Redirect Number and Name R R R 5. Select Apply Changes. Routing Inbound VoIP Calls The Inbound VoIP Call Rou
13 Rule Label To/From UC Server InboundVoipMwi Request Type Call Message Originating VoIP Host Address * * Inbound VoIP Request Matching CPID Match
14 VoIP Media Settings 1. Select Configuration > VoIP > Media 2. Ensure Voice Activity Detection is set to Off. Specific PBX Integration I
15 You must also ensure best practices to reduce or eliminate issues with fraudulent use of telecommunications services. The PBX and the UC server
16 Note: If your port number or protocol options have changed, you must stop and restart the UC Server Application Services from the Services
17 Transport Port and protocol: The transport protocol can be one of TCP, UDP or TCP and UDP. Port Number: By default, it is recommended to use IP
18 3. Leave a voice mail Place a call from one user to another and wait for the call to be transferred to voice mail. Leave a message and check th
2 Dialogic® 2000 Media Gateway Series Dialogic Part Number Description DMG2030DTI Single span T1/E1/Q.SIG Media gateway to support up to 30 channel
3 The UC server is configured to have the Primary Gateway domain/IP address. The primary gateway provides the following capabilities: 1. Message
4 o Outgoing Fax (desktop fax) o Fax-on-demand Outbound notification (database integration with outbound notification) 1. The media gateway a
5 PBX Compatibility The Dialogic Media Gateways support a number of protocols, which allows for compatibility with a wide variety of PBX systems. T
6 DMG 1000 Series Configuration - Serial Interface 1. Connect the serial cable to the serial connector on the back of the unit labeled diagnostics
7 DMG 2000 Series Configuration – Serial Interface 1. Connect the serial cable to the COM 2 connector on the gateway, and connect the other end to
8 Configuring the Media Gateway The last steps required in configuring the media gateway is to configure the dial plan, adjust the advanced setting
9 TCP/UDP UDP/TCP Transport enabled: Yes TCP/UDP Server Port: 5060 TCP Inactivity Timer (sec): 30 TLS TLS Transport Enabled: No Proxy Primary Proxy