DSI SS7HD Network Interface Boards Programmer's Manual Issue 11
53
4.2 General Configuration Messages
General configuration messages are typically issued by the s7_mgt protocol
configuration utility, in which case they need not, and should not, be generated by any
user application software.
If the user elects not to use the s7_mgt protocol configuration utility, it is necessary
for the application to build and send messages that:
configure the ssd module
reset each board
configure each board
optionally configure additional routes
The messages in the general configuration category include:
SSD_MSG_RESET - SSD Reset Request
SSD_MSG_RST_BOARD - Board Reset Request
SSD_MSG_BOARD_INFO - Board Information Request
MGT_MSG_CONFIG0 - Board Configuration Request
MGT_MSG_L1_CONFIG - Layer 1 Configuration Request
MGT_MSG_L1_END - Layer 1 Configuration End
MGT_MSG_NTP_CONFIG - Network Time Configuration