Dialogic DSI SPCI Network Interface Boards Specifiche Pagina 67

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 74
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 66
Dialogic
®
DSI SPCI Network Interface Boards Programmer's Manual Issue 7
67
State
Description
0
OK
1
PCM Loss
2
AIS
3
Sync Loss
4
Remote Alarm
Status Response
The confirmation message (if requested) indicates success by status of zero.
On error, the following status values can be found in the confirmation message.
Value
Mnemonic
Description
0x01
None
Invalid framer ID.
0xff
None
Invalid message length.